S-101
Main Specification
Solid content 100%
Gel time 10 s
Tensile strength 16MPa
Tear strength 65KN / m
Elongation 300%
Hardness,Shore A 90
Adhesion, MPa (pull method) ≥6
Acid alkali-resistance good
Density,g / cm3 1.02
Recommended thickness 1.5~3mm
Main Use
Mainly used for sewage treatment pond, drainagetrench, pickling tank, electroplating tank,evaporation pool, oil, chemicals,oil and other industries of concrete tanks and ancillary facilities,anti-corrosion waterproof.

S-102
MainSpecification
Solid content 100%
Gel time 10 s
Tensile strength 18.6MPa
Tear strength 75KN / m
Elongation 510%
Hardness,Shore A 88
Bonding strength, MPa ≥2.5 (or concretedamage)
Impermeability 0.4MPa, 2h watertight
Low temperature flexibility (-40 ℃) No break
Density,g / cm3 1.02
Recommended thickness 1~2mm
Main Use
Mainly used for roof waterproofing,reservoirs, swimming pools, aquariums, tunnel waterproofing, dams, bridges,water conservancy and other concrete structures waterproof. Also used forhigh-speed railway concrete prefabricated bridge waterproof.

S-103
MainSpecification
Solid content 100%
Gel time 10 s
Tensile strength 16MPa
Tear strength 60KN / m
Elongation 300%
Hardness,Shore A 85~95
Adhesion, MPa (pull method) ≥4
Impact resistance 1.5kg.m
Impermeability 0.4MPa, 2h watertight
Density,g / cm3 1.01
Recommended thickness 1.5~2mm
Main Use
For a variety of high-level sports venues such astennis courts, basketball courts, badminton courts, runways and so on. For allkinds of enterprises workshop floor, such as chemical plants, pharmaceuticalplants, food plants,also warehouses, car parks and so on.

S-106
MainSpecification
Solid content 100%
Gel time ≥3min
Tensile strength 16MPa
Tear strength 65KN / m
Elongation 350%
Hardness,Shore A 93
Adhesion, MPa (pull method) ≥4
Impact resistance 1.5kg.m
Impermeability 0.4MPa, 2h watertight
Density,g / cm3 1.05
Recommended thickness 1.5~2mm
Main Use
For a variety of high-level sports venues such astennis courts, basketball courts, badminton courts, runways and so on. For allkinds of enterprises workshop floor, such as chemical plants, pharmaceuticalplants, food plants,also warehouses, car parks and library,exhibition halls,science and technology museum, conference rooms and other venues.

S-401
MainSpecification
Solid content 100%
Gel time 12s
Tensile strength 25MPa
Tear strength 78KN / m
Elongation 40%
Hardness,Shore D 60~75
Adhesion, MPa (pull method) ≥8
Impact resistance 1.5kg.m
Electrical strength 20kv / mm
Salt spray resistance, 2000h No rust,no fall off,no blistering
Artificial accelerated aging No cracks, no deformation
Density,g / cm3 1.01
Recommended thickness 1~3mm
Main Use
Anti-corrosion for various types of metal chemicalequipment in the oil, chemical industry, such as chemical storage tank,pickling tank, crude oil tank, coastal steel structure, offshore drillingplatform, ship deck.

S-403
MainSpecification
Solid content 100%
Gel time 12s
Tensile strength 15MPa
Tear strength 58KN / m
Elongation 440%
Hardness,Shore A 85
Adhesion, MPa (pull method) Substrate damage
Impact resistance 1.5kg.m
Electrical strength 15kv / mm
Salt spray resistance, 2000h No rust,no fall off,no blistering
Artificial accelerated aging No cracks, no deformation
Density,g / cm3 1.01
Recommended thickness 1~3mm
Main Use
Foe toys, buildings, cartoon characters modeling,mascots; the stage, film, advertising and other props production; artificialnatural landscape; indoor and outdoor decoration materials; theme parks,amusement parks, in a variety of modeling museums ; outdoor exhibition cards,billboards, road signs.

S-406
Main Specification
Solid content 100%
Gel time 20s
Tensile strength 25MPa
Tear strength 65KN / m
Elongation 30%
Hardness,Shore D 60~75
Adhesion, MPa (pull method) ≥8
Impact resistance 1.5kg.m
Electrical strength 25kv / mm
Water resistance No rust, no fall off,noblistering
Resistant to liquid media No rust, no fall off,noblistering
Density,g / cm3 1.02
Recommended thickness 1~3mm
Main Use
Mainly used for sewage pipes, oil pipelines, gaspipes, overhead tubes, buried pipes and other pipes, the outer wall of theanti-corrosion. Can also be used for a variety of metal structure corrosion.

S-408
MainSpecification
Solid content 100%
Gel time 15s
Tensile strength 35MPa
Tear strength 90KN / m
Elongation 170%
Hardness,Shore D 70
Adhesion, MPa (pull method) 25
Impact resistance 1.5kg.m
Electrical strength 25kv / mm
Salt spray resistance, 2000h No rust,no fall off,no blistering
Resistant to liquid media No rust, no fall off,noblistering
Density,g / cm3 1.03
Recommended thickness 1~3mm
Main Use
Mainly used for high temperature requirementsoccasions, such as desulfurization tower, steam pipes and so on.

S-409
MainSpecification
Solid content 100%
Gel time 7s
Tensile strength 18MPa
Tear strength 65KN / m
Elongation 350%
Hardness,Shore A 93
Impact resistance 1.5kg.m
Electrical strength 20kv / mm
Salt spray resistance, 2000h No rust,no fall off,no blistering
Resistant to liquid media No rust, no fall off,noblistering
Density,g / cm3 1.03
Recommended thickness 1~3mm
Main Use
Mainly used for the protection of audio equipment.

S-501
MainSpecification
Solid content 100%
Gel time 10s
Tensile strength 19MPa
Tear strength 75KN / m
Elongation 300%
Hardness,Shore A 85~95
Adhesion, MPa (pull method) ≥8
Artificial accelerated aging No cracks, no deformation
Abrasion resistance(750g / 750r) <20mg
Density,g / cm3 1.01
Recommended thickness 2~15mm
Main Use
Used in the lining of mine equipment, coal minechannel, mineral transport pipeline, conveyor belt, cement mortar processingequipment; vibrating screen, spiral separator, grinding equipment, waterclassifier; for the inner surface of the ball mill to improve wear resistance.Also used for pickup trucks, container wear protection.